Seamless Connectivity for Substations
Enture OT Connector – IEC 104
Enture® OT Connector
IEC 104
Unlock Data from RTUs and Substation Gateways Instantly
IEC 60870-5-104 is the standard telecontrol protocol for power utilities, substations, and SCADA systems, extending IEC 101 over TCP/IP. Enture OT Connector – IEC 104 enables reliable, event-driven data acquisition and command/control across multiple RTUs, with stateful session handling built for the demands of grid and plant telemetry.
Specification
IEC 60870-5-104 — TCP/IP-based telecontrol protocol (standard port 2404)
APDU formats: I-format (information), S-format (supervisory), U-format (control)
Category | ASDU Types |
Single/Double Point Information | M_SP_NA_1, M_DP_NA_1 |
Measured Values | M_ME_NA_1 (normalized), M_ME_NB_1 (scaled), M_ME_NC_1 (short float) |
Integrated Totals / Counters | M_IT_NA_1 |
Time-Tagged Events (CP56Time2a) | M_SP_TB_1, M_DP_TB_1, M_ME_TE_1, M_IT_TB_1 |
Single/Double Commands (Write) | C_SC_NA_1, C_DC_NA_1 |
Setpoint Commands (Write) | C_SE_NA_1, C_SE_NB_1, C_SE_NC_1 |
General/Counter Interrogation | C_IC_NA_1, C_CI_NA_1 |
Clock Synchronization | C_CS_NA_1 |
Single Commands (C_SC_NA_1) and Double Commands (C_DC_NA_1)
Setpoint Commands — normalized, scaled, and short-float (C_SE_NA_1 / NB_1 / NC_1)
Write support with automatic queuing of write requests
Parameter | Specification |
Transport | TCP/IP, standard port 2404 (configurable) |
Session Management | Stateful session handling per RTU, with sequence number tracking (I/S/U-format) |
Timers | Configurable t1/t2/t3 timeout parameters per RTU connection |
Flow Control | Configurable k (unacknowledged APDUs) and w (acknowledgment window) parameters |
Acquisition Mode | Event-driven acquisition alongside general and counter interrogation cycles |
Redundancy | Support for redundant RTU connection groups (where configured) |
Concurrent RTUs | Multi-RTU polling and parallel communication across multiple plants/substations |
Offline Handling | Configurable wait times for offline RTUs and ongoing sessions |
Write Handling | Write support with automatic queuing of write requests |
Data Optimization | Auto-optimized polling with data compression |
Technical Higlights
Features
Key Benefits
Built for Utility & Grid Telemetry
Stateful, Resilient Sessions
Read and Write Capable
Full command/control support — single, double, and setpoint commands — with automatic request queuing.
Multi-RTU Scalability
Multi-RTU polling and parallel communication across multiple plants from a single connector instance.
Hardware-Independent Deployment
Interoperable and Hyper-Scalable Data Platform
30M+
Total incoming messages Per Day
250M+
Data Processed
95+
Sites Digitized
Enture™ seamlessly bridges OT and IT, turning data into enterprise intelligence in real time
Accelerates sustainability by enabling data-driven efficiency and resource optimization.
Enture & Sustainable Development Goals (SDGs)
With Enture, industries and cities can build a more sustainable, efficient, and climate-conscious future.